fiat132
MegaSquirt Newbie
Posts: 28
Joined: Tue Sep 20, 2005 12:22 pm
Location: EGYPT

number of squirt

Post by fiat132 »

i am running 8*180cc injectors, i couldnt get hold of larger units.i read in the manual that if you run them in alternating mode then you can have them overlap when they when you go high up the map.
the problem is...the car will only run in 1 configuration
4 squirts per cycle and simultaneous staging
it wont run on 2 squirts nor 1 squirt per cycle
its a 4 cylinder and i thought i could run it on 1 squirt per cycle
stv firestarter
MegaSquirt Newbie
Posts: 22
Joined: Sun Mar 19, 2006 12:17 pm
Location: dundee

Post by stv firestarter »

alright 132

y cant u get bigger injectors r they hard 2 come by in egipt

steve aka stv firestarter
fiat132
MegaSquirt Newbie
Posts: 28
Joined: Tue Sep 20, 2005 12:22 pm
Location: EGYPT

Post by fiat132 »

exactly....
i got it to work though...i had to change the ve table straight away to be able to catch it before it dies
the problem now ....is that it idles at.....
100% ve :shock: :shock: :shock: :shock:
i was complainig about 70....now what???
stv firestarter
MegaSquirt Newbie
Posts: 22
Joined: Sun Mar 19, 2006 12:17 pm
Location: dundee

Post by stv firestarter »

wot did u do can u tell me i c how i get on
fiat132
MegaSquirt Newbie
Posts: 28
Joined: Tue Sep 20, 2005 12:22 pm
Location: EGYPT

Post by fiat132 »

as soon as i changed the staging to alternating....it started to stumble and i had to catch it with the throttle until i increased the ve numbers.it idles even better than it was with 4 squirts but the value is too high
i will try with 1 squirt tomorrow and see how it goes
newtyres1
Helpful Squirter
Posts: 139
Joined: Mon Feb 06, 2006 7:32 pm
Location: Brisbane, Australia

Post by newtyres1 »

What is the injector opening time set to in the constants page? It should be set to 1 mS.
fiat132
MegaSquirt Newbie
Posts: 28
Joined: Tue Sep 20, 2005 12:22 pm
Location: EGYPT

Post by fiat132 »

yes it is....
FixItAgainTony
MegaSquirt Newbie
Posts: 11
Joined: Thu Feb 03, 2005 1:09 pm

Post by FixItAgainTony »

fiat132,
The following may be useful on the opening times:

http://www.msefi.com/viewtopic.php?t=17 ... sc&start=0

I have had some trouble with this myself - 4 squirts alternating worked best for me, but I am running a stock engine with stock injectors / harness. I have used a scope to calibrate opening / closing times, but it was hard to see what was going on. I will try the method in the link above next time I have a chance to play with the car.

- Charles.
Fiat - A great car for those who like to walk.
fiat132
MegaSquirt Newbie
Posts: 28
Joined: Tue Sep 20, 2005 12:22 pm
Location: EGYPT

Post by fiat132 »

i tried and while i was trying i remmebered that the manual said that the minimum with alternating was 2 squirts...
i will leave it at that...i willl have to see what kind of table which has an idle ve of 104%
:D :D :D :D
firefox

Post by firefox »

Whats your ReqFuel?