Help, can't connect to Microsquirt
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Help, can't connect to Microsquirt
Suggestions please.
Thanks,
jonathan
-
Matt Cramer
- Super Squirter
- Posts: 910
- Joined: Sat Jul 03, 2004 11:35 am
Re: Help, can't connect to Microsquirt
Re: Help, can't connect to Microsquirt
I'll get a screen shot if needed. Thanks
Re: Help, can't connect to Microsquirt

Here is a screen shot of Portchecker.exe
Re: Help, can't connect to Microsquirt
I have checked the PIN out's against the wiring diagram, I have checked the serial connections, I get Voltage on pin 13 and 14 for serial connection. -10V on red (13), and -5V on orange (14), this is with leads connected to main ground of MS and the red wire of meter connected to the respective pins listed above. is this normal?
Any direction would be appriciated.
-
pommie02
Re: Help, can't connect to Microsquirt
have you tried powering up the megasquirt and then switch on your computor, even now this is the only way i can communicate.
in windows there is a program called hyper terminal. go in to the program, name it, click on the phone connection. you need to jumper pins 5 +6 ( i think) and then just type a letter...it should bounce back.
it took me weeks to sort out my problem.
go back to the megasquirt connection problem pages, there is a better explanation there
thanks gary
Re: Help, can't connect to Microsquirt
Detected MS-II (HCS12) code.
Entry point: 0x0000
Code range : 0x4000-0x3cafc0
File read successfully.
Opened comm port 1 at 115200.
TX: 0d
Wake up attempted (9).
TX: 0d
Wake up attempted (8).
TX: 0d
Wake up attempted (7).
TX: 0d
Wake up attempted (6).
TX: 0d
Wake up attempted (5).
TX: 0d
Reopening comm port.
Wake up attempted (4).
TX: 0d
Wake up attempted (3).
TX: 0d
Wake up attempted (2).
TX: 0d
Wake up attempted (1).
TX: 0d
Wake up attempted (0).
TX: 0d
ERROR: Timed out reading response, 0xE0
Elapsed time: 19.51 seconds
-
efahl
- Site Admin
- Posts: 232
- Joined: Mon Feb 16, 2004 3:15 pm
- Location: San Clemente, California, USA
- Contact:
Re: Help, can't connect to Microsquirt
That last sequence indicates that either 1) the microSquirt isn't in boot mode, or 2) there's a hardware failure causing no communications. The fact that fuel pump output cycles (there is code running on the processor or it won't do that) plus portcheck can't connect (it wants the uS to NOT be in boot mode, which fuel pump operation confirms) narrows things down to comm hardware.
I'm not at all familiar with the microSquirt's hardware, but you need to try doing loopback tests starting with your cable then proceeding inside the uS to see where the problem lies.
Eric
Re: Help, can't connect to Microsquirt
EFIsource has issued an RMA, hopefully I'll have a new one on the way shortly.