injector question

For discussing injector selection, manifold modifications, throttle bodies, fuel supply system design and construction, and FIdle valves and IACs.
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
screamer69
MegaSquirt Newbie
Posts: 25
Joined: Mon Jul 25, 2005 2:20 pm
Location: peterborough----uk------

injector question

Post by screamer69 »

right at the moment ive running 304 cc/m@3bar but in the next week or so im putting bigger injectors in it im going to be running 440cc/m @3bar or i might up the pressure to 4bar and then they will run at 513 cc/m

so heres the question ive got a good fuel map at the mo but as soon as i change the injectors is going to be out buy a lot so is there a way of changing it so i dont have to do the fuel map again

many thanx
v3 board running extra 29k
megatune 225
2.0 8v vauxhall turbo 205bhp-232ftlbs@13psi (part mapped due to f***ed fuel pump) shes going to 28psi soon

My Success story http://www.msefi.com/viewtopic.php?p=12 ... def#129576
ronsonol
MegaSquirt Newbie
Posts: 32
Joined: Thu Sep 23, 2004 7:48 pm
Location: Kingston, ON, Canada

Post by ronsonol »

It is my understanding that all you should need to do is change the Reg_Fuel amount under injector settings, ie lower amount or use the wizard to generate the number for you. Should get you close.