extream ve table
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
-
stv firestarter
- MegaSquirt Newbie
- Posts: 22
- Joined: Sun Mar 19, 2006 12:17 pm
- Location: dundee
-
stv firestarter
- MegaSquirt Newbie
- Posts: 22
- Joined: Sun Mar 19, 2006 12:17 pm
- Location: dundee
-
newtyres1
- Helpful Squirter
- Posts: 139
- Joined: Mon Feb 06, 2006 7:32 pm
- Location: Brisbane, Australia
I just tried to rescale my VE table in Megatune 2.25, it seems to work fine. Go to Fuel tables/ve table 1/tools/ VE specific/ reset req fuel (as you did before), and put your new req fuel value in the lower box and leave the check box ticked. When you click on OK all the VE entries will be scaled down (if your new req fuel value is larger than the old one) and the engine should run exactly the same, just the VE entries will be smaller. Then go to the Constants page and verify that the req fuel value matches what you put into the new req fuel box on the VE table 1 page. Then save the changes.
Ian.
-
stv firestarter
- MegaSquirt Newbie
- Posts: 22
- Joined: Sun Mar 19, 2006 12:17 pm
- Location: dundee
-
newtyres1
- Helpful Squirter
- Posts: 139
- Joined: Mon Feb 06, 2006 7:32 pm
- Location: Brisbane, Australia
Ian.
i dont get it any more....i went to the menu u stated and made a change that made my table seem more realistic...but the car wouldnt run unlesss i raused all the values back to the same numbers.i am starting to get lost here.....isnt req fuel like a very special thing....and changing it would change the whole performance of the engine
i made alot of changes and now the car wont run...i even tried scaling the table from the tools menu but everything went crazy
whats the difference between scaling and sesetting the req fuel...to me it would make sense that scaling is what should be done to alter the numbers.....
i am getting lost here.....anyone....??????
-
jsmcortina
- MegaSquirt Guru
- Posts: 332
- Joined: Mon May 03, 2004 12:34 am
- Location: Birmingham, UK
- Contact:
Set the ReqFuel as per the Megatune calculator. Then let Megatune Generate a VE table for you, then start tuning.
Ordinarily there is no need to alter the ReqFuel again unless you change you injector size.
James
MS1/Extra at: http://www.msextra.com/manuals/MS_Extra ... _Index.htm
MS2/Extra at: http://www.msextra.com/ms2extra (runs on MS2 and Microsquirt)
-
stv firestarter
- MegaSquirt Newbie
- Posts: 22
- Joined: Sun Mar 19, 2006 12:17 pm
- Location: dundee
thanks steve
-
jsmcortina
- MegaSquirt Guru
- Posts: 332
- Joined: Mon May 03, 2004 12:34 am
- Location: Birmingham, UK
- Contact:
You didn't say what torque and power numbers you used. I made some up and tried the generate table and it doesn't look unreasonable.
Are you _really_ idling at 20kpa ? That sounds extremely low, my car idles at more like 50-60kpa.
James
MS1/Extra at: http://www.msextra.com/manuals/MS_Extra ... _Index.htm
MS2/Extra at: http://www.msextra.com/ms2extra (runs on MS2 and Microsquirt)