Dual Wideband O2 sensors ???
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Dual Wideband O2 sensors ???
Can I connect a WB O2 sensor directly to the relayboard?
Where to connect the other one?
Planning to using MS-II and EDIS on a Ford 351C V8.
-
midnightblue
- MegaSquirt Newbie
- Posts: 27
- Joined: Wed Dec 29, 2004 3:19 am
- Location: Milton Keynes, UK
You can build it in the proto area, it's only 2 resistors and a capacitor and doesn't take up much space.
Jumper the input to the new circuit out to any one of the spare pins on the DB-37 (SPR1-4) and the output to JS5 under the processor.
Select "Dual Wideband" in Megatune and you're away.