definitive MS2 settings for edis
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
-
jonfx4com
- Helpful Squirter
- Posts: 133
- Joined: Fri Nov 18, 2005 7:30 am
- Location: North of UK
- Contact:
definitive MS2 settings for edis
ignition input capture
cranking trigger
spark output (does this one matter?)
There seems to be conflicting reports of what it should be eg
http://www.msefi.com/viewtopic.php?t=15211
Which suggests that it should be inverted in some cases.
Jon
Re: definitive MS2 settings for edis
As far as I knew, ignition output should always be inverted for EDIS. In my case, WITHOUT the ignition output invereted, timing control did not work (although, the engine will still run, EDIS will just run in limp home mode @ 10deg BTDC, so don't be fooled just because the engine is running!)
Cranking triger I left default (Calculated) chaning this setting didn't seem to have much of an effect. Ignition input capture = Falling Edge.
Justin
jonfx4com wrote:Can anyone give me the definitive settings for ms2 with edis for :
ignition input capture
cranking trigger
spark output (does this one matter?)
There seems to be conflicting reports of what it should be eg
http://www.msefi.com/viewtopic.php?t=15211
Which suggests that it should be inverted in some cases.
Jon
My Success Story: http://www.msefi.com/viewtopic.php?t=11602
No problem, let me clarify though, mine only works WITH invert... I think you'll find that EDIS requires inverted mode to work.
Best of luck!
Justin
jonfx4com wrote:Thanks Justin, I at least know what to look for if the edis is stuck in limp road when I run it up at the weekend.
I post the my results back and the we can figure out why the instructions say invert and yours only works without. Weird eh?
Jon
My Success Story: http://www.msefi.com/viewtopic.php?t=11602
-
Kevin Wood
- MegaSquirt Newbie
- Posts: 6
- Joined: Mon May 03, 2004 8:58 am
- Location: Alton, Hampshire, UK
definitive MS2 settings for edis
> say invert and yours only works without. Weird eh?
I think some early EDIS instructions were advising a different way of
wiring the opto isolator such that the trigger to the CPU happens on the
opposite edge of the PIP signal.
In addition, some beta MS2s had a transistor on board for the SAW signal
which resulted in an extra inversion at the output so there are could be a
couple of variables at play. Best way to figure out if it's correct is to
look at both PIP and SAW at the EDIS on a scope. If I recall, the SAW
signal should be positive-going and start a few tens of us after the
rising edge at the back end of the PIP signal.
Kevin
Posted by email.