Via Tap In for CLT/AD2-1 ?
-
ErnieJones
- MegaSquirt Newbie
- Posts: 7
- Joined: Thu Aug 07, 2014 2:50 pm
Via Tap In for CLT/AD2-1 ?
Is there a via somewhere on the board that I can tap into for access for the CLT/AD2-1 Input?
Also, while I'm here, is there via that I can tap into for access to ALED ?
Re: Via Tap In for CLT/AD2-1 ?
-
ErnieJones
- MegaSquirt Newbie
- Posts: 7
- Joined: Thu Aug 07, 2014 2:50 pm
Re: Via Tap In for CLT/AD2-1 ?
My coolant gauge in Tuner Studio stopped working. I have continuity all the way from the sensor to the top terminal on the Microsquirt Module - so it should work but it doesn't. This leads me to believe that the problem must be before the J1 terminal on the Microsquirt. ie. between the CPU and the J1 connector. This is why I asked if anyone knows if there is a via between the J1 and the CPU that I can tap into....
Re: Via Tap In for CLT/AD2-1 ?
-
ErnieJones
- MegaSquirt Newbie
- Posts: 7
- Joined: Thu Aug 07, 2014 2:50 pm
Re: Via Tap In for CLT/AD2-1 ?
There is continuity between the CPU and that via but there is no continuity between the via/cpu pin and the Coolant Temp terminal on J2
R11 = 2.19 Ohms (spec is 2.2)
There is continuity between the via and R11
There is no continuity between J2 Pin 5 (CTS) and R11 ....
-
ErnieJones
- MegaSquirt Newbie
- Posts: 7
- Joined: Thu Aug 07, 2014 2:50 pm
Re: Via Tap In for CLT/AD2-1 ?
Conclusion - there is an issue between J2 Pin 5 and the rest of the circuit on the Microsquirt Module.
Re: Via Tap In for CLT/AD2-1 ?
Inspect the two pads on R11 for condition - are there proper solder fillets? Obvious dry joint? Try reflowing the two pads (one at a time) on R11. Also, inspect the pads and trace to R10 - a bad connection to the bias resistor will also screw up the reading.
Actually, I have to wonder if you didn't have a bad joint at J2-5, and by adding the jumper you sorted that out.
I am unaware of any pattern of complaints on the uSM and the coolant ADC ...
-
ErnieJones
- MegaSquirt Newbie
- Posts: 7
- Joined: Thu Aug 07, 2014 2:50 pm
Re: Via Tap In for CLT/AD2-1 ?
I'm now on the trail of why my external baro pressure sensor seems to be intermittently operating. I checked for continuity for all three lines including the output line all the the way up to the CPU - it's all there. I guess the question is (now) has the relatively new sensor gone south....