FAO Lance: another error in the wiring page

Forum for discussing how to install MicroSquirt(TM), choose and troubleshoot sensors, wiring, and communications for MicroSquirt (TM) and MicroSquirt Module(TM).
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
65looter
Experienced Squirter
Posts: 157
Joined: Mon Mar 27, 2006 5:56 am
Location: London
Contact:

FAO Lance: another error in the wiring page

Post by 65looter »

Lance,

I have spotted another error in the wiring of the MAP sensor:
Image

It should be:
3-bar GM Sensor
* Ground on Pin A,
* Sensor output on Pin B, and
* +5 Vref on Pin C.
according to http://www.megamanual.com/v22manual/3bar.htm

So the picture should show:
A goes to pin 20
B goes to pin 24
C goes to pin 28



Regards
Stephane