Vacuum Advance of Distributor
Forum rules
Read the manual to see if your question is answered there before posting. If you have questions about MS1/Extra or MS2/Extra or other non-B&G code configuration or tuning, please post them at http://www.msextra.com The full forum rules are here: Forum Rules, be sure to read them all regularly.
Vacuum Advance of Distributor
With and without air conditioning...
-
Mike_Robert
-
Glen Hoag
- MegaSquirt Newbie
- Posts: 6
- Joined: Sun May 02, 2004 8:57 am
- Location: Northern Alabama
- Contact:
If you are using the MegaSquirt to control timing, you should disconnect the vacuum advance (plug the hose at the other end) and adjust your timing map to accomplish the same function. That would be discussed in the ignition tuning forum.
-
Glen Hoag
- MegaSquirt Newbie
- Posts: 6
- Joined: Sun May 02, 2004 8:57 am
- Location: Northern Alabama
- Contact:
MegaSquirt accomplishes the same thing using a table, with engine speed (derived from the crank or cam sensor) and load (from the MAP sensor) as the independent variables, and the amount of advance from base timing as the result. Using a table gives you precise control over advance at all points on the timing map.