Search found 37 matches

by CHB
Wed Sep 13, 2006 7:59 am
Forum: MicroSquirt General Information
Topic: MSII engine check light?
Replies: 3
Views: 541

MSII engine check light?

is it possible to make MS II output a check light when coolant/air temperature going higher than normal?


Posted by email.
by CHB
Wed Sep 13, 2006 7:59 am
Forum: MicroSquirt General Information
Topic: MSII engine check light?
Replies: 3
Views: 541

MSII engine check light?

is it possible to make MS II output a check light when coolant/air temperature going higher than normal?
by CHB
Tue Sep 12, 2006 4:06 pm
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

can MS II control waste spark DLI without any EDIS module?

ok ok.. i'm using MS II on my toyota 3TC engine. it has a distributor to do the spark distribution.. now i try to get rid of it and plan to setup a DLI system from MS II


Posted by email.
by CHB
Tue Sep 12, 2006 4:06 pm
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

ok ok.. i'm using MS II on my toyota 3TC engine. it has a distributor to do the spark distribution.. now i try to get rid of it and plan to setup a DLI system from MS II
by CHB
Tue Sep 12, 2006 1:40 am
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

can MS II control waste spark DLI without any EDIS module?

its very hard to get a toyota GZE or 7MGTE DLI module.. so i'm looking an alternative ways to get my 3TC waste sparked..


Posted by email.
by CHB
Tue Sep 12, 2006 1:39 am
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

its very hard to get a toyota GZE or 7MGTE DLI module.. so i'm looking an alternative ways to get my 3TC waste sparked..
by CHB
Mon Sep 11, 2006 10:13 pm
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

can MS II control waste spark DLI without any EDIS module?

can MSII control a waste spark DLI without any EDIS module? currently there is only 1 Ignition output from the DB37. i wonder we can configure other additional ports to do the coil packs control?


Posted by email.
by CHB
Mon Sep 11, 2006 10:12 pm
Forum: Ignition Setup, Tuning, and Troubleshooting
Topic: can MS II control waste spark DLI without any EDIS module?
Replies: 10
Views: 1174

can MS II control waste spark DLI without any EDIS module?

can MSII control a waste spark DLI without any EDIS module? currently there is only 1 Ignition output from the DB37. i wonder we can configure other additional ports to do the coil packs control?
by CHB
Mon Sep 04, 2006 10:18 pm
Forum: Tuning Fuel and Air
Topic: Trouble setting up a toyota motor please help!
Replies: 3
Views: 389

seems you are having the same injectors as mine.. you set the injections as low impedence or high impedence(with resistor pack in series with the injectors)?
by CHB
Fri Sep 01, 2006 12:14 am
Forum: Tuning Fuel and Air
Topic: starting issues
Replies: 3
Views: 423

i experienced the same problem too.. but i can't pressed on the throttle at all. have to crank the engine for at least 6 times without opening the throttle. the engine did started when i cranked it but dies immediately after that. after 5-7 tries, it can started on its own but once u step on the ...